<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-20 12-08-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
90.90 MHz 5/5, 56 dBuV HELSINKI
Pilot RDS Phase Difference
7.5 kHz 3.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 70 kHz 18951 0,0528
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-3,7 dBr 2,53 dBr 4,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"HELSINKI" 6092 10 (Pop M) 1 0 1 7 --:--
RT
" Olet ystävien seurassa "
AF EON
89.7, 90.9 MHz -
FM Scope Max at: 70 kHz MIN: 10 kHz % above 76 kHz: 0,0528 Acquired: 2025/08/20 12.07.44 Total samples: 18951 Equivalent time: 0:15:47 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,4 dBr MIN: -3,7 dBr AVE: 2,53 dBr % above 12,2 dBr: 0,0 Last value: 2,6 dBr (2025/08/20 12.07.44) 11.54 11.56 11.58 12.00 12.02 12.04 12.06 -4 -2 0 2 4 Pm [dBr]